Choose an Ethernet cable by port speed and total run length

Two Ethernet patch leads with rectangular network connectors
Contents
  1. Read the port speeds before you shop
  2. Count the wall run and both patch leads
  3. Verify the link you paid for
  4. Frequently asked questions

Use Cat6 for a typical gigabit patch lead. For a new 10-gigabit copper run through walls, choose Cat6A if you want a channel specified for up to 100 meters. Cat8 is aimed at short 25GBASE-T and 40GBASE-T copper channels. It cannot raise the speed of a 1 Gbps port.

Read the port speeds before you shop

Find the Ethernet speed in each device's specification. If a switch sits between the devices, check the speeds of the ports on both sides of that switch. An internet speed test alone cannot tell you whether the local link is 1 Gbps or 10 Gbps.

CableWhen it fitsDistance to check
Cat6Normal gigabit wiring or a suitable existing short 10G pathGigabit channels up to 100 m. Existing Cat6 at 10G needs qualification, including crosstalk conditions.
Cat6AA new 10GBASE-T run through a home or officeUp to 100 m for the full channel
Cat8Compatible 25GBASE-T or 40GBASE-T copper portsUp to 30 m for a compliant channel

A Category 8 patch cord is a component. The end-to-end channel also depends on the jacks, patch leads, installation, shielding and terminations. A port with an SFP28 cage, for example, needs a compatible link type or transceiver. Check the equipment specification for the port you will actually use. What a switch does between two devices

Count the wall run and both patch leads

A 60 m cable inside the walls plus a 2 m patch lead at each end makes a 64 m channel. For a new 10GBASE-T installation at that length, specify Cat6A for the complete channel. A short Cat8 lead in the same room will leave the rest of the installed path unchanged.

If you already have Cat6 and want to repurpose it for 10G, ask an installer to qualify the existing channel. The TIA guidance submitted to the IEEE 10GBASE-T work includes a 55 m Cat6 case and accounts for interference from nearby cables. Treat the run length and crosstalk conditions together.

Need the login details for your router? Look up the default IP address, username and password for your brand.

Find your router’s default login

Start with a short known-good lead between two ports that support the target speed. Check the negotiated link rate in the switch or adapter status. Then connect through the installed run and check again. If it drops to a lower rate, inspect or test the jacks, patch cords, and terminations before buying higher-category cable. A reported link rate is an initial check. Certification can catch channel problems that a successful startup will miss. How to isolate an Ethernet cable fault

Frequently asked questions

Is Cat8 worth buying for a gigabit router?

A sound Cat6 cable already supports the port's gigabit rate. A Cat8 marking does not change the speed the ports negotiate.